Material Properties: G-10 CR (Fiberglass Epoxy)

Data Available:

 

Thermal Conductivity
(Normal Direction)

Thermal Conductivity
(Warp Direction)

Specific Heat

UNITS W/(m-K) W/(m-K) J/(kg•K)
a -4.1236 -2.64827 -2.4083
b 13.788 8.80228 7.6006
c -26.068 -24.8998 -8.2982
d 26.272 41.1625 7.3301
e -14.663 -39.8754 -4.2386
f 4.4954 23.1778 1.4294
g -0.6905 -7.95635 -0.24396
h 0.0397 1.48806 0.015236
i 0 -0.11701 0
data range
4-300 4-300 4-300
equation range
10-300 12-300 4-300
curve fit % error relative to data
5 5 2
Curve fit equation of the form:
log10 y = a+b(log10T) + c(log10T) 2 + d(log10T) 3 + e(log10T) 4 + f(log10T) 5 + g(log10T) 6 + h(log10T) 7 + i(log10T) 8


Solves as:
y = 10
a+b(log10T) + c(log10T) 2 + d(log10T) 3 + e(log10T) 4 + f(log10T) 5 + g(log10T) 6 + h(log10T) 7 + i(log10T) 8

Where: Coefficients a - i are summarized in the appropriate table and T is the temperature in K (x-axis), and y is the property to solve for.

See References

Linear Expansion
(normal direction)
Linear Expansion
(warp direction)
.UNITS
[(L-L293)/L293] x 105 unitless, eg. m/m [(L-L293)/L293] x 105 unitless, eg. m/m
a
-7.198E2 -2.469E2
b
4.455E-1 2.064E-1
c
7.505E-3 3.072E-3
d
-2.219E-6 -3.226E-6
e
0 0
Tlow (K)
NA NA
f>
NA NA
data range (K)
4-300 4-300
equation range (K)
10-300 12-300
curve fit % error relative to data
1.5 2
equation of the form:
y = a + bT + cT 2 + dT 3 + eT 4
   >T > Tlow
y = f 
   T < Tlow
solves as expected: Where: Coefficients a-e are summarized in the appropriate table and T is the temperature in K (x-axis), and y is the property to solve for.

See References

Return to Material Properties Index page