p-T-x Measurements for Some Working Fluids for an Absorption Heat Transformer: 1,1,1,2-Tetrafluoroethane (R134a) + Dimethylether Diethylene Glycol (DMEDEG) and Dimethylether Triethylene Glycol (DMETrEG)
Zehioua, R.[Raouf], Coquelet, C.[Christophe], Meniai, A. H.[Abdeslam Hassen], Richon, D.[Dominique]
The solubilities of 1,1,1,2-tetrafluoroethane (R134a), CF3CH2F, + dimethylether diethylene glycol (DMEDEG), CH3O(CH2CH2O)2CH3, and R134a + dimethylether triethylene glycol (DMETrEG) binary systems were measured, using the static-analytic method at temperatures between (303 and 353) K. This work was an opportunity to test the use of R134a as a refrigerant in combination with an organic absorbent, like DMEDEG and DMETrEG, in an absorption heat transformer (AHT), also known as a type II absorption heat pump or a reversed absorption heat pump. The experimental data were correlated using the Peng-Robinson equation of state (PR-EoS) in combination with Mathias-Copeman a function, Huron-Vidal mixing rules, and the nonrandom two-liquid (NRTL) activity coefficient model. The experimental results were compared to the predicted values obtained using the predictive Soave-Redlich-Kwong group contribution equation of state (PSRK-EoS).
Compounds
#
Formula
Name
1
C2H2F4
1,1,1,2-tetrafluoroethane
2
C6H14O3
2,5,8-trioxanonane
3
C8H18O4
2,5,8,11-tetraoxadodecane
Datasets
The table above is generated from the ThermoML associated json file (link above).
POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied;
the numbers refer to the table of compounds on the left.