Liquid-Liquid Equilibria for the Ternary System Methyl Isobutyl Ketone + Water + Hydroquinone

Yang, C.[Chufen], Jiang, Y.[Yanbin], Zhang, L.[Lijuan], Qian, Y.[Yu]
J. Chem. Eng. Data 2006, 51, 6, 2107-2109
ABSTRACT
Experimental liquid-liquid equilibria data of dilute hydroquinone concentration were determined for the ternary system methyl isobutyl ketone + water + hydroquinone at (25, 40, and 50) deg C under atmospheric pressure. The experimental data were satisfactorily correlated with the UNIQUAC equation and the NRTL equation. The relative root-mean-square deviations and absolute mean deviations between the calculated and the experimental value are less than 1.2 %.
Compounds
# Formula Name
1 C6H6O2 1,4-benzenediol
2 C6H12O 4-methylpentan-2-one
3 H2O water
Datasets
The table above is generated from the ThermoML associated json file (link above). POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied; the numbers refer to the table of compounds on the left.
Type Compound-# Property Variable Constraint Phase Method #Points
  • POMD
  • 2
  • 3
  • Mass fraction - 2 ; Liquid mixture 2
  • Temperature, K; Liquid mixture 2
  • Pressure, kPa; Liquid mixture 1
  • Liquid mixture 2
  • Liquid mixture 1
  • Chromatography
  • 3
  • POMD
  • 2
  • 3
  • Mass fraction - 3 ; Liquid mixture 1
  • Temperature, K; Liquid mixture 1
  • Pressure, kPa; Liquid mixture 1
  • Liquid mixture 1
  • Liquid mixture 2
  • Chromatography
  • 3
  • POMD
  • 2
  • 1
  • 3
  • Mass fraction - 2 ; Liquid mixture 2
  • Mass fraction - 3 ; Liquid mixture 1
  • Mass fraction - 2 ; Liquid mixture 1
  • Temperature, K; Liquid mixture 1
  • Mass fraction - 3; Liquid mixture 2
  • Pressure, kPa; Liquid mixture 1
  • Liquid mixture 2
  • Liquid mixture 1
  • Chromatography
  • Chromatography
  • Chromatography
  • 30