Thermodynamics Research Center / ThermoML | Journal of Chemical and Engineering Data

Densities and Heat Capacities of the Ammonia + Water + NaOH and Ammonia + Water + KOH Solutions

Salavera, D.[Daniel], Libotean, S.[Simona], Patil, K. R., Esteve, X.[Xavier], Coronas, A.[Alberto]
J. Chem. Eng. Data 2006, 51, 3, 1020-1025
ABSTRACT
Ammonia + water + sodium hydroxide and ammonia + water + potassium hydroxide mixtures were chosen as potential candidates for absorption chillers driven by low-temperature heat sources. Heat capacity and density were studied between (293.15 and 353.15) K at a constant pressure of 1.8 MPa for these solutions using a heat flux Calvet-type calorimeter and a vibrating-tube densimeter, respectively. Measured data were well-correlated with temperature and composition using simple polynomial equations. The relative deviations between the experimental and calculated values in the density and heat capacity measurements were 0.20 % and 0.49 % for NH3 + H2O + NaOH solutions and 0.10 % and 0.36 % for NH3 + H2O + KOH solutions, respectively. Also, two density prediction methods were checked using the experimental data. Previously, it was necessary to measure the density of ammonia and hydroxide aqueous solutions in similar conditions. The results showed that both methods are suitable for predicting the density of these solutions.
Compounds
# Formula Name
1 H2O water
2 H3N ammonia
3 HNaO sodium hydroxide
4 HKO potassium hydroxide
Datasets
The table above is generated from the ThermoML associated json file (link above). POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied; the numbers refer to the table of compounds on the left.
Type Compound-# Property Variable Constraint Phase Method #Points
  • POMD
  • 3
  • 2
  • 1
  • Molar heat capacity at constant pressure, J/K/mol ; Liquid
  • Temperature, K; Liquid
  • Mass fraction - 2; Liquid
  • Mass fraction - 3; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • LDSC:UFactor:0.5
  • 47
  • POMD
  • 3
  • 2
  • 1
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Mass fraction - 2; Liquid
  • Mass fraction - 1; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method
  • 35
  • POMD
  • 4
  • 2
  • 1
  • Molar heat capacity at constant pressure, J/K/mol ; Liquid
  • Temperature, K; Liquid
  • Mass fraction - 2; Liquid
  • Mass fraction - 4; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • LDSC:UFactor:0.5
  • 54
  • POMD
  • 4
  • 2
  • 1
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Mass fraction - 2; Liquid
  • Mass fraction - 4; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method
  • 35