ABSTRACT
An adiabatic calorimeter was used to measure the enthalpy of fusion of a sample of high-purity bismuth. The new value of the enthalpy of fusion was determined to be Hfus = (53.146 +/- 0.082) J.g-1, where the uncertainty corresponded to a 95% confidence interval. The temperature of fusion of this sample was found not to differ with previous accurate determinations within the accuracy of the fusion-temperature determination made in the present study. A comparison with some other enthalpy of fusion determinations is made.
Compounds
# Formula Name
1 Bi bismuth
Datasets
The table above is generated from the ThermoML associated json file (link above). POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied; the numbers refer to the table of compounds on the left.
Type Compound-# Property Variable Constraint Phase Method #Points
  • POMD
  • 1
  • Molar enthalpy of transition or fusion, kJ/mol ; Crystal
  • Crystal
  • Liquid
  • Gas
  • Adiabatic calorimetry
  • 1
  • POMD
  • 1
  • Triple point temperature, K ; Crystal
  • Crystal
  • Liquid
  • Gas
  • Adiabatic calorimetry
  • 1