Isothermal Vapor-Liquid Equilibrium Data for the Systems 1,4-Dioxane + Water + Tetrabutylammonium Nitrate and Acetonitrile + Water + Tetrabutylammonium Bromide
Kurzin, A. V.[Alexander V.], Evdokimov, A. N.[Andrey N.], Poltoratskiy, G. M.[Gennadiy M.], Platonov, A. Y.[Andrew Yu.], Gusev, V. E.[Vladimir E.], Golubeva, Y. M.[Yulia M.]
Isothermal vapor-liquid equilibrium data for the system 1,4-dioxane + water + tetrabutylammonium nitrate at 11 constant salt molalities ((0.1, 0.25, 0.50, 0.75, 1.00, 1.50, 2.00, 2.50, 3.00, 3.50, and 4.00) mol?kg-1) have been measured with the help of gas chromatography at (288, 298, and 308) K. Isothermal vapor-liquid equilibrium data for the system acetonitrile + water + tetrabutylammonium bromide at 5 constant salt molalities ((0.20, 0.40, 0.60, 0.80, and 1.00) mol?kg-1) have also been measured with the help of gas chromatography at (298 and 323) K. The experimental data for these systems were correlated using the electrolyte nonrandom two-liquid model.
Compounds
#
Formula
Name
1
C4H8O2
1,4-dioxane
2
H2O
water
3
C16H36N2O3
tetrabutylammonium nitrate
4
C16H36BrN
tetrabutylammonium bromide
5
C2H3N
acetonitrile
Datasets
The table above is generated from the ThermoML associated json file (link above).
POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied;
the numbers refer to the table of compounds on the left.