Total Pressure Phase Equilibrium Measurements for the Binary Systems of n-Pentane + Cyclohexane and 1-Hexene + 2-Propanol

Naicker, Sivanna, Nelson, Wayne Michael, Naidoo, Paramespri, Ramjugernath, Deresh
J. Chem. Eng. Data 2018, 63, 12, 4741-4748
ABSTRACT
Phase equilibrium data were measured for the binary systems of n-pentane + cyclohexane at (293.20, 298.17 and 303.17) K and 1-hexene + 2-propanol at (293.18, 303.17 and 313.16) K. The experimental measurements were conducted using a static-synthetic total pressure apparatus. The overall compositional data (T-P-z) were converted to the co-existing phases at equilibrium (T-P-x-y) using material balances and thermodynamic models. The thermodynamic models followed the combined method featuring either the Wilson or NonRandom Two-Liquid activity coefficient models, and the Ideal Gas Law. The models provided an excellent fit to the experimental data. The binary system of 1-hexene + 2propanol exhibited positive deviation from Raoult's law resulting in the formation of a homogeneous azeotrope for the all the measured isotherms.
Compounds
# Formula Name
1 C5H12 pentane
2 C6H12 cyclohexane
3 C6H12 hex-1-ene
4 C3H8O propan-2-ol
Datasets
The table above is generated from the ThermoML associated json file (link above). POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied; the numbers refer to the table of compounds on the left.
Type Compound-# Property Variable Constraint Phase Method #Points
  • POMD
  • 1
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method
  • 1
  • POMD
  • 1
  • Refractive index (Na D-line) ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Standard Abbe refractometry
  • 1
  • POMD
  • 1
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 8
  • POMD
  • 2
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method
  • 1
  • POMD
  • 2
  • Refractive index (Na D-line) ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Standard Abbe refractometry
  • 1
  • POMD
  • 2
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 8
  • POMD
  • 3
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method
  • 1
  • POMD
  • 3
  • Refractive index (Na D-line) ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Standard Abbe refractometry
  • 1
  • POMD
  • 3
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 8
  • POMD
  • 4
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method
  • 1
  • POMD
  • 4
  • Refractive index (Na D-line) ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Standard Abbe refractometry
  • 1
  • POMD
  • 4
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 8
  • POMD
  • 1
  • 2
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 62
  • POMD
  • 3
  • 4
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Mole fraction - 3; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 64