Density is one of the most important thermophysical properties of aviation fuel for the advanced fuel-cooled thermal management. The density of a hydrocarbon fuel JP-10 was measured using a gamma-ray radial method calibrated with deionized water, cyclohexane and a mixture of n-heptane and n-octane. The average absolute deviation (AAD) of deionized water is 0.22% under 3.0 MPa and 0.43% under 5.0 MPa, of cyclohexane is 0.80% under 5.0 MPa, of the mixture of n-heptane and n-octane is 0.33% under 5.1 MPa. The experimental density of JP-10 was reported at (267 to 873) K under
Compounds
#
Formula
Name
1
C10H16
exo-tetrahydrodicyclopentadiene
Datasets
The table above is generated from the ThermoML associated json file (link above).
POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied;