ABSTRACT
A variable volume apparatus of low cell volume (approximately 10 cm3) was designed and commissioned for measuring phase equilibrium and thermodynamic property data. The experimental procedure and equipment capability for phase equilibrium measurements were validated by measuring isothermal phase equilibrium (T-P-x) data for binary mixtures involving carbon dioxide + n-hexane and ethane + n-octane. There is good agreement between data measurement using the new equilibrium cell and previous measurements reported in the literature. New T-P-x data were also measured for the binary mixture of ethane + 2,2,4-trimethylpentane. The data were correlating using the Peng-Robinson Equation of State and the van der Waals mixing rule. The expanded uncertainties in the measurements were evaluated as 0.07 K, 0.01 MPa, and 0.008 for the temperature, pressure, and liquid mole fraction, respectively.
Compounds
# Formula Name
1 CO2 carbon dioxide
2 C2H6 ethane
3 C6H14 hexane
4 C8H18 2,2,4-trimethylpentane
5 C8H18 octane
Datasets
The table above is generated from the ThermoML associated json file (link above). POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied; the numbers refer to the table of compounds on the left.
Type Compound-# Property Variable Constraint Phase Method #Points
  • POMD
  • 1
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 1
  • POMD
  • 2
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 1
  • POMD
  • 3
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method
  • 1
  • POMD
  • 3
  • Refractive index (Na D-line) ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Standard Abbe refractometry
  • 1
  • POMD
  • 4
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method
  • 1
  • POMD
  • 4
  • Refractive index (Na D-line) ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Standard Abbe refractometry
  • 1
  • POMD
  • 5
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method
  • 1
  • POMD
  • 5
  • Refractive index (Na D-line) ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Standard Abbe refractometry
  • 1
  • POMD
  • 2
  • 5
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Mole fraction - 2; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 11
  • POMD
  • 1
  • 3
  • Vapor or sublimation pressure, kPa ; Liquid
  • Mole fraction - 1; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 9
  • POMD
  • 2
  • 4
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Mole fraction - 2; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 44