Thermodynamics Research Center / ThermoML | Thermochimica Acta

Temperature and pressure dependence of densities and viscosities for binary mixtures of methyl decanoate plus n-heptane

Su, Chao, Zhu, Chenyang, Lai, Tianwang, Wang, Tao, Liu, Xiangyang, He, Maogang
Thermochim. Acta 2018, 670, 211-218
ABSTRACT
New experimental densities and viscosities data for binary mixtures of methyl decanoate plus n-heptane were reported at temperatures of (298.15, 308.15 and 318.15) K and pressures of (0.1-15) MPa. The expanded uncertainty for density measurement is estimated to be 2 kg m-3 and the relative expanded uncertainty for viscosity measurement is estimated to be 0.03. A fitting equation was proposed to correlate the density of the binary mixture and Grunberg-Nissan equation was used to predict the viscosity of the binary mixture, respectively. The maximum absolute relative deviations between the experimental results and calculation values for densities and viscosities were 0.11% and 5.94%, respectively.
Compounds
# Formula Name
1 C11H22O2 methyl decanoate
2 C7H16 heptane
Datasets
The table above is generated from the ThermoML associated json file (link above). POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied; the numbers refer to the table of compounds on the left.
Type Compound-# Property Variable Constraint Phase Method #Points
  • POMD
  • 1
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Siemens Coriolis flowmeter
  • 18
  • POMD
  • 1
  • Viscosity, Pa*s ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Capillary tube (Ostwald; Ubbelohde) method
  • 18
  • POMD
  • 2
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Siemens Coriolis flowmeter
  • 18
  • POMD
  • 2
  • Viscosity, Pa*s ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Capillary tube (Ostwald; Ubbelohde) method
  • 18
  • POMD
  • 1
  • 2
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Siemens Coriolis flowmeter
  • 198
  • POMD
  • 1
  • 2
  • Viscosity, Pa*s ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Capillary tube (Ostwald; Ubbelohde) method
  • 198