Thermodynamics Research Center / ThermoML | Journal of Chemical Thermodynamics

Vapour-liquid equilibria, enthalpy of vaporisation, and excess Gibbs energies of binary mixtures of {3,3-diamino-N-methyldipropylamine (DNM) (or N,N,N',N'',N''-pentamethyldiethylenetriamine (PMDETA)) + water}

Mahi, Mohammed Ridha, Bouzina, Zahida, Mokbel, Ilham, Negadi, Amina, Goutaudier, Christelle, Jose, Jacques, Negadi, Latifa
J. Chem. Thermodyn. 2019, 128, 251-258
ABSTRACT
The vapour pressures of the pure components 3,3-diamino-N-methyldipropylamine (DNM) and N,N,N',N'',N''-pentamethyldiethylenetriamine (PMDETA) along with the binary mixtures (DNM + water) and (PMDETA + water) were measured by means of a static apparatus at temperatures between (283 and 363) K. The data were correlated with the Antoine equation. From these data, excess Gibbs functions (GE) were calculated for several constant temperatures and fitted to four order Redlich-Kister equation using the Barker method. The binary system (DNM + water) exhibits negative deviations in GE values calculated from the vapour pressure data for all investigated temperatures and over the whole composition range. The (PMDETA + water) binary mixture shows a sinusoidal shape for GE at 283.15 K less than T less than 303.15 K, and a positive deviation in GE for [313.15 - 363.15] K temperature range. Additionally, the NRTL, UNIQUAC models have been used for the correlation of prediction of the total pressure.
Compounds
# Formula Name
1 C7H19N3 N-(3-aminopropyl)-N-methyl-1,3-propanediamine
2 C9H23N3 N,N,N',N'',N''-pentamethyldiethylenetriamine
3 H2O water
Datasets
The table above is generated from the ThermoML associated json file (link above). POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied; the numbers refer to the table of compounds on the left.
Type Compound-# Property Variable Constraint Phase Method #Points
  • POMD
  • 1
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 30
  • POMD
  • 2
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 15
  • POMD
  • 1
  • 3
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 63
  • POMD
  • 2
  • 3
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Mole fraction - 2; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 63