Thermodynamics Research Center / ThermoML | Journal of Chemical Thermodynamics

Experimental determination of critical data of multi-component mixtures containing potential gasoline additives 2-butanol by a flow-type apparatus

He, M.[Maogang], Xin, N.[Nan], Wang, C.[Chengjie], Liu, Y.[Yang], Zhang, Y.[Ying], Liu, X.[Xiangyang]
J. Chem. Thermodyn. 2016, 101, 35-43
ABSTRACT
In this work, we used a flow method for measurement of critical properties of six binary mixtures (2-butanol + cyclohexane, 2-butanol + hexane, 2-butanol + heptane, 2-butanol + octane, 2-butanol + nonane and 2-butanol + decane) and two ternary mixtures (2-butanol + hexane + heptane and 2-butanol + octane + decane). The critical properties were determined by observing the disappearance and reappearance of the gas liquid phase meniscus in a quartz glass tube. The standard uncertainties of temperatures and pressures for both binary and ternary mixtures were estimated to be less than 0.2 K and 5.2 kPa, respectively. These critical data provide the boundaries of the two-phase regions of the related mixture systems. Six binary systems show non-ideal behaviors in the loci of critical temperatures. We used the Redlich Kister equations to correlate the critical temperatures and pressures of these systems and listed the binary interaction parameters. The maximum average absolute deviation (AAD) of each binary system between experimental data and calculated results from Redlich Kister equations is 0.038% for critical temperatures, and 0.244% for critical pressures. Moreover, the two ternary systems were newly reported and correlated by Cibulka s and Singh s expressions. The maximum AAD of critical temperatures and critical pressures are 0.103% and 0.433%, respectively.
Compounds
# Formula Name
1 C4H10O butan-2-ol
2 C6H14 hexane
3 C6H12 cyclohexane
4 C7H16 heptane
5 C8H18 octane
6 C9H20 nonane
7 C10H22 decane
Datasets
The table above is generated from the ThermoML associated json file (link above). POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied; the numbers refer to the table of compounds on the left.
Type Compound-# Property Variable Constraint Phase Method #Points
  • POMD
  • 1
  • Critical temperature, K ; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 1
  • POMD
  • 1
  • Critical pressure, kPa ; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 1
  • POMD
  • 2
  • Critical temperature, K ; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 1
  • POMD
  • 2
  • Critical pressure, kPa ; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 1
  • POMD
  • 3
  • Critical temperature, K ; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 1
  • POMD
  • 3
  • Critical pressure, kPa ; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 1
  • POMD
  • 4
  • Critical temperature, K ; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 1
  • POMD
  • 4
  • Critical pressure, kPa ; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 1
  • POMD
  • 5
  • Critical temperature, K ; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 1
  • POMD
  • 5
  • Critical pressure, kPa ; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 1
  • POMD
  • 6
  • Critical temperature, K ; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 1
  • POMD
  • 6
  • Critical pressure, kPa ; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 1
  • POMD
  • 7
  • Critical temperature, K ; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 1
  • POMD
  • 7
  • Critical pressure, kPa ; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 1
  • POMD
  • 1
  • 2
  • Critical temperature, K ; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 11
  • POMD
  • 1
  • 2
  • Critical pressure, kPa ; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 11
  • POMD
  • 1
  • 3
  • Critical temperature, K ; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 11
  • POMD
  • 1
  • 3
  • Critical pressure, kPa ; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 11
  • POMD
  • 1
  • 4
  • Critical temperature, K ; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 11
  • POMD
  • 1
  • 4
  • Critical pressure, kPa ; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 11
  • POMD
  • 1
  • 5
  • Critical temperature, K ; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 11
  • POMD
  • 1
  • 5
  • Critical pressure, kPa ; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 11
  • POMD
  • 1
  • 6
  • Critical temperature, K ; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 11
  • POMD
  • 1
  • 6
  • Critical pressure, kPa ; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 11
  • POMD
  • 1
  • 7
  • Critical temperature, K ; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 11
  • POMD
  • 1
  • 7
  • Critical pressure, kPa ; Liquid
  • Mole fraction - 1; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 11
  • POMD
  • 1
  • 2
  • 4
  • Critical temperature, K ; Liquid
  • Mole fraction - 1; Liquid
  • Mole fraction - 2; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 18
  • POMD
  • 1
  • 2
  • 4
  • Critical pressure, kPa ; Liquid
  • Mole fraction - 1; Liquid
  • Mole fraction - 2; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 18
  • POMD
  • 1
  • 5
  • 7
  • Critical temperature, K ; Liquid
  • Mole fraction - 1; Liquid
  • Mole fraction - 5; Liquid
  • Liquid
  • Gas
  • Visual observation in an unstirred cell
  • 18
  • POMD
  • 1
  • 5
  • 7
  • Critical pressure, kPa ; Liquid
  • Mole fraction - 1; Liquid
  • Mole fraction - 5; Liquid
  • Liquid
  • Gas
  • Direct measurement
  • 18