Thermodynamics Research Center / ThermoML | Journal of Chemical Thermodynamics

Measurements of (vapour + liquid) equilibrium data for {trifluoroiodomethane (R13I1) + isobutane (R600a)} at temperatures between (263.150 and 293.150) K

Guo, H.[Hao], Gong, M.[Maoqiong], Dong, X.[Xueqiang], Wu, J.[Jianfeng]
J. Chem. Thermodyn. 2013, 58, 428-431
ABSTRACT
This paper contains the measurements of isothermal VLE data for the binary system {trifluoroiodomethane (R13I1) + isobutane (R600a)} at four temperatures from (263.15 to 293.15) K. The measurements are performed by means of an apparatus based on the static analytic method. The combined standard uncertainties of the measured results are +-5 mK for temperature, +-0.00025 MPa for pressure, +-0.005 for mole fraction of the liquid and vapour composition. The VLE data are correlated with the Peng Robinson equation of state and the Huron Vidal mixing rules involving the NRTL activity coefficient model. The model is successfully verified to be suitable for calculating the VLE data of the system measured. The experimental results show that {trifluoroiodomethane (R13I1) + isobutane (R600a)} is a zeotropic system.
Compounds
# Formula Name
1 CF3I trifluoroiodomethane
2 C4H10 2-methylpropane
Datasets
The table above is generated from the ThermoML associated json file (link above). POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied; the numbers refer to the table of compounds on the left.
Type Compound-# Property Variable Constraint Phase Method #Points
  • POMD
  • 1
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 4
  • POMD
  • 2
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 4
  • POMD
  • 2
  • 1
  • Vapor or sublimation pressure, kPa ; Liquid
  • Mole fraction - 1; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 36
  • POMD
  • 2
  • 1
  • Mole fraction - 1 ; Gas
  • Mole fraction - 1; Liquid
  • Temperature, K; Liquid
  • Gas
  • Liquid
  • Chromatography
  • 36