Thermodynamics Research Center / ThermoML | Journal of Chemical Thermodynamics

Study of the effects of pressure on the viscosity and density of diisodecyl phthalate

Paredas, X.[Xavier], Fandino, O.[Olivia], Comunas, M. J. P.[Maria J.P.], Pensado, A. S.[Alfonso S.], Fernandez, J.[Josefa]
J. Chem. Thermodyn. 2009, 41, 9, 1007-1015
ABSTRACT
In the present work viscosity data for three different samples with two different purity grades of diisodecyl phthalate (DIDP) are reported from 303.15 K to 373.15 K up to 60 MPa, together with density values from 283.15 K to 398.15 K and up to 70 MPa. The experimental measurements have been performed with a rotational automated viscometer Anton Paar Stabinger SVM3000, a rolling-ball viscometer Ruska 1602-830 for high pressures and a recently automated Anton Paar DMA HPM vibrating-tube densimeter. The measured data for viscosity have been compared with previous literature values and could be useful to establish together with previous viscosity data, a correlation of the full viscosity surface ?(T, P) of DIDP. This correlation is needed for the calibration and verification of high-pressure viscometers at moderate viscosities.
Compounds
# Formula Name
1 C28H46O4 3-methylnonyl 1,2-benzenedioate
Datasets
The table above is generated from the ThermoML associated json file (link above). POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied; the numbers refer to the table of compounds on the left.
Type Compound-# Property Variable Constraint Phase Method #Points
  • POMD
  • 1
  • Viscosity, Pa*s ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Air at 1 atmosphere
  • Rotational Automated Viscometer
  • 20
  • POMD
  • 1
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Air at 1 atmosphere
  • SVM3000 rotational viscometer
  • 20
  • POMD
  • 1
  • Viscosity, Pa*s ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Falling or rolling sphere viscometry
  • 45
  • POMD
  • 1
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method
  • 70
  • POMD
  • 1
  • Viscosity, Pa*s ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Air at 1 atmosphere
  • Rotational Automated Viscometer
  • 20
  • POMD
  • 1
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Air at 1 atmosphere
  • SVM3000 rotational viscometer
  • 20
  • POMD
  • 1
  • Viscosity, Pa*s ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Falling or rolling sphere viscometry
  • 45
  • POMD
  • 1
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method
  • 70
  • POMD
  • 1
  • Viscosity, Pa*s ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Air at 1 atmosphere
  • Rotational Automated Viscometer
  • 20
  • POMD
  • 1
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Air at 1 atmosphere
  • SVM3000 rotational viscometer
  • 20
  • POMD
  • 1
  • Viscosity, Pa*s ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Falling or rolling sphere viscometry
  • 27
  • POMD
  • 1
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method