Thermodynamics Research Center / ThermoML | Fluid Phase Equilibria

Isothermal vapor liquid equilibrium data for the decafluorobutane(R3110) + 1,1,1,3,3-pentafluorobutane (R365mfc) system attemperatures from 333 K to 441 K

Madani, H.[Hakim], Valtz, A.[Alain], Coquelet, C.[Christophe]
Fluid Phase Equilib. 2013, 354, 109-113
ABSTRACT
The organic Rankine cycle (ORC) is one solution to recover energy from high temperature hot sources.It requires working fluid with high critical coordinate values. It is named for its use for an organichigh molecular masse fluid with a liquid vapor phase change. The knowledge of phase diagram ofworking fluid is a crucial task in refrigeration process. In this context, a new mixture of decafluo-robutane (R3110) and 1,1,1,3,3-pentafluorobutane (R365mfc), is studied by means of experimentalmeasurements and modeling procedures. The purpose is to obtain the isothermal vapor liquid equi-librium data (R3110 + R365mfc) of binary system ranging from (333.26 to 441.61) K temperature, and(0.2016 to 3.0927) MPa pressure. The data were obtained with accurate within u(T, k = 2) = 0.02 K, u(P,k = 2) = 0.0003 MPa and u(z) = 0.004 for molar composition. In the present work, the static analytic methodis another time investigated to achieve a high quality data as it was largely demonstrated previouslyby the team of our laboratories. The experimental data are correlated using the classical equations:Peng Robinson equation of state, the Mathias Copeman alpha function, and the Wong Sandler mixingrules involving the NRTL model. The predicted critical line is well reproduced.
Compounds
# Formula Name
1 C4F10 decafluorobutane
2 C4H5F5 1,1,1,3,3-pentafluorobutane
Datasets
The table above is generated from the ThermoML associated json file (link above). POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied; the numbers refer to the table of compounds on the left.
Type Compound-# Property Variable Constraint Phase Method #Points
  • POMD
  • 2
  • Vapor or sublimation pressure, kPa ; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 24
  • POMD
  • 1
  • 2
  • Vapor or sublimation pressure, kPa ; Liquid
  • Mole fraction - 1; Liquid
  • Temperature, K; Liquid
  • Liquid
  • Gas
  • Closed cell (Static) method
  • 75
  • POMD
  • 1
  • 2
  • Mole fraction - 1 ; Gas
  • Mole fraction - 1; Liquid
  • Temperature, K; Liquid
  • Gas
  • Liquid
  • Chromatography
  • 75