Thermodynamics Research Center / ThermoML | Fluid Phase Equilibria

Compressed liquid densities of 1,1,1,3,3-pentafluoropropane (HFC-245fa) and 1,1,1,3,3,3-hexafluoropropane (HFC-236fa)

Yin, J.[Jianguo], Wu, J.[Jiangtao]
Fluid Phase Equilib. 2011, 307, 1, 1-5
ABSTRACT
Densities of 1,1,1,3,3-pentafluoropropane (HFC-245fa) and 1,1,1,3,3,3-hexafluoropropane (HFC-236fa) have been measured for temperatures from 293 to 373 K and pressures up to 70 MPa, with a high-pressure vibrating tube densimeter system in the liquid state. The system was calibrated using water and vacuum via the method of Lagourette et al. The uncertainty in the density measurement was estimated to be +-0.6 kg m-3. The experimental results were correlated to a Tait equation. The average absolute percentage deviations of measurement results from the correlations of HFC-245fa and HFC-236fa are 0.0096% and 0.031%, respectively.
Compounds
# Formula Name
1 C3H3F5 1,1,1,3,3-pentafluoropropane
2 C3H2F6 1,1,1,3,3,3-hexafluoropropane
Datasets
The table above is generated from the ThermoML associated json file (link above). POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied; the numbers refer to the table of compounds on the left.
Type Compound-# Property Variable Constraint Phase Method #Points
  • POMD
  • 1
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method
  • 114
  • POMD
  • 2
  • Mass density, kg/m3 ; Liquid
  • Temperature, K; Liquid
  • Pressure, kPa; Liquid
  • Liquid
  • Vibrating tube method
  • 111