Thermodynamics Research Center / ThermoML | International Journal of Thermophysics

Measurements of Hydrogen Thermal Conductivity at High Pressure and High Temperature

Moroe, S., Woodfield, P. L., Kimura, K., Kohno, M., Fukai, J., Fujii, M., Shinzato, K., Takata, Y.
Int. J. Thermophys. 2011, 32, 9, 1887-1917
ABSTRACT
The thermal conductivity for normal hydrogen gas was measured in the range of temperatures from 323 K to 773 K at pressures up to 99 MPa using the transient short hot-wire method. The single-wire platinum probes had wire lengths of 10 mm to 15 mm with a nominal diameter of 10 im. The volume-averaged transient temperature rise of the wire was calculated using a two-dimensional numerical solution to the unsteady heat conduction equation. A non-linear least-squares fitting procedure was employed to obtain the values of the thermal conductivity required for agreement between themeasured temperature rise and the calculation. The experimental uncertainty in the thermal-conductivity measurements was estimated to be 2.2 % (k = 2). An existing thermal-conductivity equation of state was modified to include the expanded range of conditions covered in the present study. The new correlation is applicable from 78 K to 773 K with pressures to 100 MPa and is in agreement with the majority of the present thermal-conductivity measurements within +-2 %.
Compounds
# Formula Name
1 H2 hydrogen
2 He helium
Datasets
The table above is generated from the ThermoML associated json file (link above). POMD and RXND refer to PureOrMixture and Reaction Datasets. The compound numbers are included in properties, variables, and phases, if specificied; the numbers refer to the table of compounds on the left.
Type Compound-# Property Variable Constraint Phase Method #Points
  • POMD
  • 1
  • Thermal conductivity, W/m/K ; Fluid (supercritical or subcritical phases)
  • Pressure, kPa; Fluid (supercritical or subcritical phases)
  • Temperature, K; Fluid (supercritical or subcritical phases)
  • Fluid (supercritical or subcritical phases)
  • Hot wire method
  • 198
  • POMD
  • 2
  • Thermal conductivity, W/m/K ; Fluid (supercritical or subcritical phases)
  • Pressure, kPa; Fluid (supercritical or subcritical phases)
  • Temperature, K; Fluid (supercritical or subcritical phases)
  • Fluid (supercritical or subcritical phases)
  • Hot wire method
  • 121